10
OPERATION
STARTING THE ENGINE
NOTE:
Before starting the engine, do not connect any electric devices.
1. Turn the fuel switch lever to the “ON” position.
2. Turn the engine switch to the “ON” position.
3. Hold the choke knob fully out for a cold start.
Note: Sometimes the choke is required to start a warm engine.
4. Pull slowly on the recoil starter until it is engaged, then pull it briskly. (Electric start model press engine
start button to start.)
5. After the engine starts, warm up the engine until the engine does not stop when the choke knob is returned
to the original position.
6. Push the choke knob back to the original position.
NOTE:
When starting the engine in areas where the ambient temperature is below 0°/32° F run the engine for one
to three minutes to warm up the engine.
ECONOMY CONTROL SWITCH
Engine speed is kept at idle automatically when the electrical device is disconnected and is returned to the
proper speed by the electrical load when the electrical device is reconnected. The economy control switch
in “ON” position is recommended to minimize the fuel consumption while in normal operation.
NOTE:
When high electrical load devices are connected simultaneously, turn the economy control switch to the
“OFF” position, the engine speed will increase to reduce voltage changes. Otherwise the generator will not
operate suf ciently to run high demand electrical devices.